Home Page

Contact Us

My Basket

Checkout

U1208LOG USB DAQ Unit/Data Logger


Description

 

The U1208LOG is a PC based USB data acquisition module with a stand-alone data logging capability. Data can be logged to a standard USB memory stick, with Log file capacity only limited by the USB flash drive size. The U1208LOG also has the functionality to record video from cameras, syncronised with analogue data recording. (PC acquisition only - not to flash memory).

The U120816 comes with all free usb cable, screw driver, device driver, DLL, LabVIEW driver, dot net wrapper class, rich examples and free ready-to-run iDAQTest&Log testing and data logging software

 

Product

 

 

(USB Memory Stick Not Included)

User Manual >>

Accessories >>

 

 

PC Data Acquisition

  • 8 Single-Ended, 12-Bit Analogue Inputs

  • 0-4.096 V Analogue Input Range
  • Up to 64 kSamples/Sec Throughput with Single Channel
  • Up to 13kSamples/Second for Streaming Mode on all 8 channels
  • Supports Both Scan Mode and Continuous Streaming Mode Data Acquisition
  • One Dedicated Trigger Line for Streaming Mode Data Acquisition
  • Two programmable 10-bit PWM Outputs (3kHz- 333kHz)
  • 16 Bi-Directional Digital I/O Lines (125HZ update rate)
  • One 16-Bit Counter
  • 240 bytes EEPROM Reserved for User Data
  • Multiple iUSBDAQs Can Be Connected On Same Computer
  • Simultaneous Streaming from Multiple iUSBDAQs Possible
  • Works with Windows 2000, or WinXP, MacOSX, windows Vista (32bit).
  • FREE Downloadable Device Driver, Programming API (DLL), LabVIEW Drivers, VB Examples, ActiveX example, dot net example, C/C++ example, Delphi, MacOSX
  • FREE Standalone Ready-to-Run iDAQTest&Log Software for Testing, Data Logging, Data Playback and Simple Analysis

 

Stand-alone Data Logger

  • Log 8 analogue inputs, 16 digital inputs and one 16 bit counter

  • Data storage to standard USB Memory stick
  • Log file size only limited by USB memory stick size.
  • Can be powered by PC USB bus or from included mains PSU
  • All data are time stamped.
  • Logging interval/frequency from 1 second to 12 hours, unlimited log period as long as USB disk has enough free space.
  • Logging frequency configurable with FREE iDAQTest&Log software
  • Automatic file name creation with time stamp.
  • On board lithium battery to power the real time clock. Date/time setting of real time clock on board is configurable with iDAQTest&Log software
  • Dedicated log "trigger out" line for synchronization of external devices.

 

Video Functions

  • Real time video display along with the data readings

  • AVI recording along with data recording
  • Playback AVI file along with data
  • Dedicated video "trigger out" line
  • Work with USB webcam or firewire camera that supports WDM driver or are directshow compliant

 

Analogue Inputs

 

These are 8 single ended analogue input channels. It has a range of 0-4.096V, 12 bit, so the resolution would be 1mv. The U1208LOG supports scan and streaming modes for data acquisition. The user can scan a single channel or scan multi-channels at once. In scan mode, the execution time is 4ms or 250Hz per channel.

In streaming mode, the U1208LOG can start streaming data to the PC immediately or upon external trigger input, select through software. In trigger mode, a high state on the trigger line will start the data acquisition. The maximum throughput of streaming data varies with number of channels and they are also system dependant.

Typically this is up to 64Ksamples/s for a single channel and 26Ksamples/s for all 8 channels.

 

Digital I/O

 

There are 16 bi-directional digital I/O lines in U1208LOG module. Each line is software configurable to be either input or output high or output low. At power-up or reset, all lines are set to be input by default. All digital lines are 5V TTL and include a 470 ohm series resistor to provides overvoltage/short-circuit protection. Each channel also has a 1 M resistor connected to ground.

Trigger

This is the external trigger line for streaming mode data acquisition. It is software configurable if the user wants to wait for this line. When in use, as soon as the line goes high, the device will start hardware timed data acquisition. This is a TTL level input.

PWM

There are two 10-bit PWM outputs in U1208LOG. Software can set the period and duty cycle for each channel separately. The period is between 3 micro seconds to 333 micro seconds or the frequency is 333kHz to 3kHz. Duty cycle can be set between 0 – 100%. The PWM outputs can be used to light LEDs, drive motors, or convert to analogue outputs by adding an extra circuit.

Counter

The U1208LOG has a 16-bit counter. Software has the option to select if the counter should be reset after the read or not. The counter is incremented when it detects a falling edge followed by a rising edge. If you reset the counter while your signal is low, you will not get the first count until it goes high-low-high again.

 

Data Logging Mode

 

The U1208LOG can be used as stand alone data logger. The connector USB2 is used for connecting a USB flash memory stick disk, while USB1 connector is used for PC control or for the power adaptor. The logging interval by default is 1 second, user can change this value in iDAQTest&Log software. It’s between 1 second to 12 hours.

The U1208LOG has a switch located beside the USB2 connector. On switching to PC/Stop side, this will allow the module to be controlled by PC. By switching to LOG/Start side, it will work as a standalone data logger and PC will not recognize this device when in LOG mode

When in logger mode, the U1208LOG will automatically generate a new log file name whenever the USB flash disk is inserted into USB2 connector or when the log file has logged over 30,000 scans of data (each scan includes 8 analogue inputs , 16 digital inputs and one counter channel).

 

Software

 

iDAQTest&Log

iDAQTest&Log is a free standalone ready-to-run software package that can be used to test the U1208LOG device and log analogue input data and read back logged data for basic analysis. With this software, the user can browse through all the features in U1208LOG, such as read single analogue channel, multiple analogue channels, streaming analogue input data continuously for display and log into file with or without external trigger, set DIO directions and read/write DIO states, set PWM output, read counter etc.

 

Analogue Input Tab - shows analogue input readings, plots all 8 inputs on a chart display, and has data logging configuration, where the log file name and sample rate can be specified (slowest speed is 128 samples/sec)

Digital I/O Tab - In this tab user can set digital I/O directions, write output lines and read the DIO states.

Counter Tab - In this counter tab, user can read counter, reset counter. A rising edge on the counter pin will increment counter. Counter will roll over after 65536 (16 bit)

PWM Output Tab - Set the PWM output. There are two 10-bit PWM channels, ch1 and ch2. The PWM period is between 3- 333micro second. Duty cycle is between 0 -100.

Analysis Graph Tab - The user can load a saved data file in this tab. iDAQTest&Log provides limited analysis function, user can view the multi-plot graph. Two cursors can be used for measuring the data points. The XY axis by default is in auto scale mode, right click on the graph, a popup menu will appear, user can turn auto scale on or off or just click on the axis’ number to change the graph range. Future version will provide more analysis functions in this tab.

Video and Data

In this tab, the user can select a directshow supportied USB webcam or firewire camera. The software will display live video synchronized with the 8 analogue inputs, 16 DIOs and counterinput, record AVI file and data, playback AVI file with data etc. Up to 3 cameras listed and up to 5 seconds video clip and data can be recorded.

 
Programming

The U1208LOG device driver installs the programming API iUSBDAQ.dll into the computer system’s directory. This DLL can be called by third party applications. Programming examples are supplied in VB , ActiveX , dot net , C/C++ , Delphi, MacOSX.

LabVIEW

Supplied with LabVIEW VI's. The LabVIEW interface VI's are a wrapper around iUSBDAQ.dll. Full function call descriptions are described in the user manual.

 

Accessories

 

USB Active Extender

USB-EXT

 

A USB cable cannot be used reliably used where the distance is greater than 5m. For distances greater than this, an active USB repeater is required

  • Connect up to 4 repeaters in series

  • No external power required
  • USB 1.1 and 2.0
  • each repeater is 5m long

 

USB Active Extender CAT5

USB-CAT5

 

Overcome USB's 5m transmission limitation by using this extender along with standard network cable. Can extend USB by up to 45m.

  • Use standard CAT 5/5e/6 RJ45 cable to interconnect

  • works up to 45m
  • Master - RJ45 female, USB A male via lead
  • Remote - RJ45 female, USB A socket
  • No external power required
  • USB 1.1 only

NOTE - not supplied with RJ45 cable - just Master and Remote units

 

 

Phone +44(0)115 925 8412 | Fax +44(0)115 925 9757