Poseidon 3268 Temp/Humidity Monitor


Description

 

The Poseidon model 3268 is a simple Ethernet based stand-alone device which can send an email alarm when up to 4 monitored temperature or humidity sensors exceeds their defined range. The Poseidon 3268 also has 4 dry-contact inputs which can also be used to generate alarms and 2 relay outputs for control purposes. Sensor monitoring and configuration is available via a web-based graphic interface or data can be viewed via several network protocols such as SNMP, XML, and Modbus/TCP.

 

Product

 

User Manual >>

 

  • Ethernet - RJ45 connection

  • Up to 4 temperature or temperature/humidity sensors located up to 10m away
  • Sensors connected via 1-wire bus
  • 4 Contact closure inputs via screw terminals
  • 2 Relay outputs for control
  • Simple web interface for configuration and control
  • Open communications protocols (SNMP, XML, Modbus/TCP and others..)
  • Can be used with SCADA software such as DAQFactory
  • Supplied with basic copy of CapTemp software
  • Supplied with basic copy of nmsDashboard software
  • Alarm on input
    • E-mail (SMTP)
    • SNMP Trap
    • SMS via software
  • Free SDK (Software Development Kit) library with examples (Visual Basic, Delphi, C++, .NET ...)

 

Description

 

The Poseidon 3268 is a simple Ethernet based stand-alone device which can send an email alarm when up to 4 monitored temperature or humidity sensors exceeds their defined range.

The 3266 also has 4 contact-closure inputs which can be used to trigger alarms on state change and there are 2 relay outputs which can be used to reset servers, or switch on a fan, etc.

Temperature or combined temperature/humidity sensors can be connected via RJ11 cable using the 1-wire protocol. Sensors are simply connected in a serial chain using RJ11 cable. These can be up to 10m away from the Poseidon 3268.

Once the Poseidon 3268 is connected to the Ethernet, you can run the free UDP setup utility, which will serch the LAN to find all attached devices. You can then specify your desired Network address parameters. Once this is done, you can simply acces the I/O data from a web browser. There is also a flash-based version.

You can assign a name to each sensor and also define high and low alarm limits. When the parameter goes outside these limits, the Poseidon 3266 can send user defined email alarm messages.

All sensor's values as well as alarm status information are available from XML files (temper.xml) and any application can log it from XML tags. The Poseidon 3268 also supports the Modbus TCP protocol, so it is easy to integrate with common SCADA packages such as DAQFactory

 

 

Typical Applications

  • Monitoring of temperature in server location, independent monitoring over GSM network - notifies of alarm via SMS

  • Monitoring of working conditions (temperature and humidity) of ICT technologies (server, safety and phone systems, etc.)
  • Monitoring of server rooms, air-conditioned 19“ racks, switch-boards and servers
  • Monitoring of back-up power sources, UPS and Diesel engines
  • Monitoring and logging of conditions in storage buildings, cold-storage buildings, freezers and fridges (food and pharmacy industry)
  • Extended intelligent buildings – air-condition and heating optimalization, long term monitoring of living conditions
  • Air-condition working monitoring, monitoring of evaporated water leaking

 

Sensors and Cables

 

Temperature Sensor with Cable

 

  • -55°C to +125°C temperature range

  • indoor use only
  • ±0.5°C resolution
  • 1-Wire® DS18B20 IC
  • 3m cable length

TAI8520 Temperature Module

 

  • -50°C tp 55°C temperature range

  • indoor use only
  • ±0.5°C resolution
  • 1-Wire® DS18B20 IC
  • 1-wire in and 1-wire out RJ11 connectors
  • All power supplied via 1-wire cable
  • Unique 1-Wire address permits multiple sensors on the network

TEMP-RACK19 Temperature Sensor

 

  • -55°C to +125°C temperature range

  • indoor use only
  • ±0.5°C resolution
  • 1-Wire® DS18B20 IC
  • supplied with 3m cable
  • 19" 1U device fitted to side of the cabinet.

TAI8540D Humidity Module

 

  • 0% to 100% RH range

  • Measures Relative Humidity with a ±2% accuracy
  • 1-Wire® DS2438 IC
  • 1-wire in and 1-wire out RJ11 connectors
  • All power supplied via 1-wire cable
  • Unique 1-Wire address permits multiple sensors on the network

T-Box Sensor Expansion

  • Allows up to 5 sensors to be connected to a Poseidon Unit

1WC-3M - 3m Expansion Cable

 

PowerEgg - Mains Switch/Monitor

 

  • Switches mains power via digital or contact input

  • Returns main on/off status via contact output
  • IEC input/output connectors
  • Controls fully isolated from mains
  • 110 to 230VAC, switches up to 8A
  • Control signal either contact closure or 3-12V DC

User Manual >>

 

Software Applications

 

nmsDashboard

nmsDashboard utilises standard TCP/IP and application protocols to query and monitor network devices and their associated services. nmsDashboard is designed to provide the user with a simple yet powerful mechanism through which they can observe the activity on and respond to alarms raised from their network 24 hours a day, 7 days a week. Free 3-sensor verson supplied with the Poseidon 3265.

 

CapTemp

Simple to use Data Logging and Alarm software package for use with all Poseidon units. Sensor information can be desplayed in both numeric and graphical formats. Data from several Poseidon units can be logged to a single Excel-compatible data file.

 

DAQFactory

Control and monitoring software DAQFactory can be used with the Poseidon 3265 with version that have the connectivity pack. Uses the Modbus TCP protocol. DAQFactory can be used to create an opertor interface, with plant mimics, chart recorders, provide automatic control, PID loops, alarms and datalogging and reporting functions.

 

 

Specifications

 

Ethernet port

Interface

RJ45 (10BASE-T) 10 Mbit or 10/100 Mbit network compatible

Supported protocols

IP: ARP, TCP/IP (HTTP, Modbus over TCP), UDP/IP (SNMP)

SNMP compatibility

Ver:1.00 compatible, some parts of the ver 2.0 implemented

Sensor port

 Connector

RJ11/12 1-wire

 Sensors

Up to 4 sensors with 10m max total cable length

Contact Inputs

Type

NO or NC dry contact switch

Relay Outputs

Type

Change-over contacts, 50V DC, max DC current 24V/1A, 50V/0.5A

LED Status indicators

POWER

Green - power OK

LINK & Activity

Green - Ethernet connectivity

 

DIP SWITCH configuration

DIP1  

ON = RS-232 Setup mode over Port 1 (RS-232 mode only) OFF = Run mode

DIP2   - Security

ON   = Security mode - remote configuration disabled
OFF = Non-Security mode - remote configuration enabled

 

Physical parameters

Voltage requirements

9-15 V/ 250 mA DC- power connector, GND on the shield

Dimensions

35 x 101 x 76 [mm] (H x W x D )

Weight

150 g

 

Functional parameters

Device SETUP configuration possibilities

- UDP Config - IP address assign via UDP
- TCP Setup - Terminal configuration and sensors management
- WWW Setup - HTTP Flash application
- SNMP (just for some parameters)

 

 

Phone +44(0)115 925 8412 | Fax +44(0)115 925 9757