Home Page

Contact Us

My Basket

Checkout

MS6D 16-Ch Universal Input Data Logger


Description

 

The MS6D is a stand-alone datalogger with 16 universal inputs, accepting volts, 4-20mA current loops, thermocouples and PT100 temperature sensors, resistances and digital signals. Fearturing a large 2M data memory, LCD display, alarms and USB interface for programming and data download. An optional RS485 interface allows datalogging from MODBUS devices and an optional Ethernet interface adds email alerts, web interface and SNMP notification.

 

Product

 

 

User Manual >>

 

 

  • 16-channel 16-bit universal input datalogger;

    • ±10V, ±1V, ±100mV, ±18mV
    • type K, J, S, B, T thermocouples
    • PT100, PT1000, Ni1000 resistance thermometers
    • two-wire resistance 0-300ohm, 0-3000ohm, 0-10kohm
    • digital or contact closure input
  • All inputs software configurable
  • 2MB Memory (up to 480 000 recorded values) internal backed-up SRAM
  • Data logging intervals: from 1 second to 24 hours
  • LCD and keypad for local display and configuration
  • Communication interface;
    • USB for configuration and data download
    • RS232 for configuration and data download, GSM modem support for remote config and SMS alerts
    • RS485 (Optional) - multi-drop several MS6D to a PC or connect RS485 devices to the MS6D
    • Ethernet (Optional) - web interface, SNMP, emailetc
  • Hi/Low alarm per input with LED indication, Relay output ( 1 x 8A/250Vac) SMS messages (GSM option), E-mails, SNMP traps (Ethernet option)

 

Models

 

 

 

MS6D

  • for desktop or wall mounting

  • Dimensions - 215 x 225 x 44 mm (W x D x H)
  • Protection: IP20
  • Operating temperature range: 0 to +50°C
  • Power: 24Vdc, approximately 80 mA

 

MS6D

 

MS6R

  • for mounting to 19" rack - one rack unit 1U or for desktop use

  • Dimensions - 225 x 230 x 44 mm (W x D x H)
  • Protection: IP20
  • Operating temperature range: 0 to +50°C
  • Power: 24Vdc, approximately 80 mA

 

MS6R

 

General

 

The MS6D is a stand-alone datalogger with 16 universal inputs, accepting volts, 4-20mA current loops, thermocouples and PT100 temperature sensors, resistances and digital signals. Fearturing a large 2M data memory, LCD display, alarms and USB interface for programming and data download. An optional RS485 interface allows datalogging from MODBUS devices and an optional Ethernet interface adds email alerts, web interface and SNMP notification.

Features

  • Configure inputs for different signal types from the PC program or using the LCD and keypad.

  • Individully configure each input channel for measurement, alarm evaluation and data logging , including individual logging interval for each input.
  • Individually program each input channel for different modes of record (continuous record, time dependent record, record only if specified logic conditions are matched, record triggered by external signal, etc.).
  • Set up to four different logic conditions for each channel to active alarm. Each condition compares measured values from inputs with set limits. It is possible to set hysteresis and delay of condition validity.
  • Indicate alarm state after matching defined combination up to four alarms from any inputs.
  • Activate selected relays depending on alarm states by means of output relays module.
  • Receive information from monitoring system by means of SMS messages via GSM modem - actual values, alarms, memory occupation etc.
  • Assign to each input channel name of actual recorded process to identify monitored object (e.g. type of monitored product). It is enabled to select this name from data logger keyboard during the operation.

 

Software

 

Also included is a USB communication cable of approximately 1.8 meter length and free program for Windows.

Program enables control all logger functions and to view and print the recorded data in numerical format. It is possible to export recorded data to dbf or xls formats for further analysis, e.g. in MS Excel.

For work with graphs and other functions is possible to order optional program SWR006 or Database MS Program SWR008 - see Optional Accessories.

Download >>

 

 

Accessories

 

RS485 Option

 

  • Input is designed for reading from devices supporting protocol ModBus RTU or Advantech.

  • Input can work wit up to 16 devices.
  • Maximum speed 115200Bd.
  • Galvanically isolated.

MS6D-RS485IN

Ethernet Option

 

 

Built-in LAN interface for MS6D, MS6R data logger connection to Ethernet (Internet) network. Communication via: SNMP, SOAP, www pages. In case of limits exceeding alarm is activated and warning e-mail or SNMP trap are sent to specified addresses.

 

MP042

MS6D Mounting Brackets

 

 

Universal metal wall holders for recorder mounting. Package contains a pair of holders and 4 screws.

LP013

Advanced Datalogging Software

 

 

Optional software for Windows - easyto use graphical environment data acquisition, including online graph, automatic data download, remote Display mode on Internet-Ethernet network, storing data on the network, administration of users and passwords and many others ..

SWR006

 

Database MS Program

Program package Database MS Program for work with data from Comet MSx loggers.

  • To view selected channels from any Comet logger together with selected channels of other Comet loggers.

  • Measurement from different Comet devices is possible to combine in one table or graph.
  • To choose any time interval for analysis.
  • Print, export to PDF - table and graph.

SWR008

For database viewing by other users at the network it is necessary to buy proper number of licences of Database Viewer.

SWR010

 

Input Ranges

 

Input Range

Accuracy

Note

 

 

 

dc current
4 to 20 mA

±0.1% FS (±0.02mA)

either from active source connected between COM and GND terminals or passive sensor connected between terminals +24V and COM

dc voltage
-10V to +10V

±0.1% FS
(±10 mV)

input resistance approximately 10 Mohms,
input terminals IN and COM

dc voltage
-1V to +1V

±0.1% FS
(±1 mV)

input resistance approximately 10 Mohms,
input terminals IN and COM

dc voltage
-100mV to +100mV

±0.1% FS
(±100 uV)

input resistance approximately 10 Mohms,
input terminals IN and COM

dc voltage
-18mV to +18mV

±0.1% FS
(±18 uV)

input resistance approximately 10 Mohms,
input terminals IN and COM

thermocouple K (NiCr-Ni)
-200 to +1300°C

±0.3% from reading + 1.5°C

linearized, cold junction compensation,
input terminals IN and COM

thermocouple J (Fe-Co)
-200 to +750°C

±0.3% from reading + 1.5°C

linearized, cold junction compensation,
input terminals IN and COM

thermocouple S (Pt10%Rh-Pt)
0 to +1700°C

±0.3% from reading + 1.5°C

linearized, cold junction compensation,
input terminals IN and COM

thermocouple B (Pt30%Rh-Pt)
+100 to +1800°C

±0.3% from reading + 1.0°C
od +300 to +1800°C

linearized,
without cold junction compensation,
input terminals IN and COM

thermocouple T (Cu-CuNi)
-200 to +400°C

±0.3% from reading + 1.5°C

linearized, cold junction compensation,
input terminals IN and COM

Platinum temperature sensor Pt100
-200 to +600°C

±0.2°C
od -200 to +100°C
±0.2% from reading from +100 to +600°C

two-wire connection, measuring current approximately 0.8mA in pulse 50ms,
input terminals IN and COM

Platinum temperature sensor Pt1000
-200 to +600°C

±0.2°C
od -200 to +100°C
±0.2% from reading from +100 to +600°C

two-wire connection, measuring current approximately 0.5mA in pulse 50ms,
input terminals IN and COM

Nickel temperature sensor
Ni1000/6180ppm
-50 to +250°C

±0.2°C
od -50 to +100°C
±0.2% from reading from +100 to +250°C

two-wire connection, measuring current approximately 0.5mA in pulse 50ms,
input terminals IN and COM

two-wire measurement of resistance
0 to 300 Ohms

0.1% FS
(±0.3 Ohms)

measuring current approximately 0.8mA / 50ms,
input terminals IN and COM

two-wire measurement of resistance
0 to 3000 Ohms

0.1% FS
(±3 Ohms)

measuring current approximately 0.5mA / 50ms,
input terminals IN and COM

two-wire measurement of resistance
0 to 10000 Ohms

0.1% FS
(±10 Ohms)

measuring current approximately 0.1mA / 50ms,
input terminals IN and COM

 

 

Phone +44(0)115 925 8412 | Fax +44(0)115 925 9757