Input
Range |
Accuracy |
Note |
|
|
|
|
|
|
|
|
|
dc
current
4
to 20 mA |
±0.1%
FS (±0.02mA) |
either
from active source connected between COM and GND terminals or
passive sensor connected between terminals +24V and COM |
|
|
|
dc
voltage
-10V
to +10V |
±0.1%
FS
(±10
mV) |
input
resistance approximately 10 Mohms,
input
terminals IN and COM |
|
|
|
dc
voltage
-1V
to +1V |
±0.1%
FS
(±1
mV) |
input
resistance approximately 10 Mohms,
input
terminals IN and COM |
|
|
|
dc
voltage
-100mV
to +100mV |
±0.1%
FS
(±100
uV) |
input
resistance approximately 10 Mohms,
input
terminals IN and COM |
|
|
|
dc
voltage
-18mV
to +18mV |
±0.1%
FS
(±18
uV) |
input
resistance approximately 10 Mohms,
input
terminals IN and COM |
|
|
|
thermocouple
K (NiCr-Ni)
-200
to +1300°C |
±0.3%
from reading + 1.5°C |
linearized,
cold junction compensation,
input
terminals IN and COM |
|
|
|
thermocouple
J (Fe-Co)
-200
to +750°C |
±0.3%
from reading + 1.5°C |
linearized,
cold junction compensation,
input
terminals IN and COM |
|
|
|
thermocouple
S (Pt10%Rh-Pt)
0
to +1700°C |
±0.3%
from reading + 1.5°C |
linearized,
cold junction compensation,
input
terminals IN and COM |
|
|
|
thermocouple
B (Pt30%Rh-Pt)
+100
to +1800°C |
±0.3%
from reading + 1.0°C
od
+300 to +1800°C |
linearized,
without
cold junction compensation,
input
terminals IN and COM |
|
|
|
thermocouple
T (Cu-CuNi)
-200
to +400°C |
±0.3%
from reading + 1.5°C |
linearized,
cold junction compensation,
input
terminals IN and COM |
|
|
|
Platinum
temperature sensor Pt100
-200
to +600°C |
±0.2°C
od
-200 to +100°C
±0.2%
from reading from +100 to +600°C |
two-wire
connection, measuring current approximately 0.8mA in pulse 50ms,
input
terminals IN and COM |
|
|
|
Platinum
temperature sensor Pt1000
-200
to +600°C |
±0.2°C
od
-200 to +100°C
±0.2%
from reading from +100 to +600°C |
two-wire
connection, measuring current approximately 0.5mA in pulse 50ms,
input
terminals IN and COM |
|
|
|
Nickel
temperature sensor
Ni1000/6180ppm
-50
to +250°C |
±0.2°C
od
-50 to +100°C
±0.2%
from reading from +100 to +250°C |
two-wire
connection, measuring current approximately 0.5mA in pulse 50ms,
input
terminals IN and COM |
|
|
|
two-wire
measurement of resistance
0
to 300 Ohms |
0.1%
FS
(±0.3
Ohms) |
measuring
current approximately 0.8mA / 50ms,
input
terminals IN and COM |
|
|
|
two-wire
measurement of resistance
0
to 3000 Ohms |
0.1%
FS
(±3
Ohms) |
measuring
current approximately 0.5mA / 50ms,
input
terminals IN and COM |
|
|
|
two-wire
measurement of resistance
0
to 10000 Ohms |
0.1%
FS
(±10
Ohms) |
measuring
current approximately 0.1mA / 50ms,
input
terminals IN and COM |
|
|