MBIO-16DO - 16 Channel Digital/Transistor Output

MBIO-16DO - 16 Channel Digital/Transistor Output
Zoom  Zoom
Our Price:  £59.00(£70.80 Inc. VAT)

Digital Outputs:  16

Availability:  

4 in stock, immediate despatch  

4 in stock, immediate despatch

Low-cost Modbus RS485 based remote IO units, which provide a simple way for integrating analogue or digital signals to supervisory SCADA systems. The MBIO-16DO has 16 NPN open collector transistor outputs.


Special Offer:  Discounts of 7%, 10%, 12.5% and 15% are available when you order 10, 25, 50 and 100 items or more of this product.

  • 16 Digital Outputs
  • Type - NPN Open collector
  • Max Load Current - 100mA per channel
  • Max load Voltage - 36Vdc
  • Watch dog output timer     Disable or 1-255 sec  adjustable
  • Isolation (Field & Logic) - 1500VAC RMS
  • Status Indication - LED per channel
  • Operating Temperature. -10°C to + 50°C
  • Power Supply - 12-24V DC (30mA @12V, 17mA @24V)
  • Dimensions - 100mm x 90mm x 25mm (excluding screw terminals)

This module has 16 open collector (NPN) digital outputs. The outputs may be used to drive lamps or external relays when more drive capability is required. The outputs are isolated from the logic and they share a common negative terminal.

Each output can be individually switched on or off, or all outputs can be set up at the same time by writing a single number to the output register which represents the status of all outputs.

The module may be used as either a slave or master on the Modbus network. When used with a PC or PLC the module will be configured as a slave. When used with a MBIO-16DI module in a point-to-point configuration, the DIP switch 9 must be turned on to set the module up as a master. In this mode the MBIO-16DO module will automatically read the information from the MBIO-16DI module and write the input status to the outputs. The two modules must have the same  network ID and these must be the only modules on the network.

An output watchdog timer can be configured to switch off all the outputs if there has been no communications with the module for up to 255 seconds. A value of 0 seconds will disable this timer and the outputs will remain in the last programmed state.

Configuration Software

IOStudio is a free software package used to configure the communication settings for IO modules on the Modbus network. Once a module is detected, it is possible to view real-time data of the module directly on the PC and it can be used for diagnostic purposes as well.

 