Description

 

The Site-Log LPTM-1 is an 7-channel, battery powered, stand alone thermocouple data logger. The logger records up to 4Mb of data and stores it in non-volatile flash memory for later retrieval. In addition to thermocouples, Site-Log LPTM-1 can also be used as a small voltage data logger with the input voltage range as small as -8 mV to +8 mV.

Featuring an aluminum enclosure and conformal coating PCB, the Site-Log data logger has excellent performance in the harshest industrial environment. Featuring a 16-bit ADC and programmable input range, the Site-Log data loggers are well suited to science and laboratory applications where precise and accurate measurement is critical.

 

Features

 

 
LPTM-1
Supplied with USB lead

SiteView software purchased separately >>

User Manual >>

 

  • 7 x thermocouple inputs - type B, E, J, K, N, R, S, T and -8mV to 73mV

  • internal temperature channel (-40°C ~ 70°C)
  • 16-bit analogue-to-digital converter
  • 4 mega-byte memory size
  • Overvoltage Protection: up to +/- 40VDC
  • Both USB and serial interfaces with auto baud rate of up to 115 kbps
  • Power: Built-in 3.6V Lithium Battery.
  • Over 10 years of battery Life (can be changed)
  • Powerful SiteView software (purchased separately >>) for configuration, downloading, plotting, analysis and alarm reporting -Configurable Alarm Control/Excitation Controls
  • Channel Alarms: Two editable alarm thresholds per channel
  • Wide sampling rate (20 milliseconds to 12 hours)
  • Excitation Control: power control to external devices - only powers sensors to take a reading
  • DIN rail or wall mount
  • Dimension: 88 X 64.2 X 24 mm
  • Coated to protect against moisture, corrosion and mildew.  

Description

 

The Site-Log datalogger range are portable battery powered data loggers which allow recording information and saving measurements to a 4MB flash memory for later retrieval. The internal lithium battery provides up to 10 years of instantaneous logging operation when sampling at interval of one minute. Site-Log data loggers features a wide sampling interval range from 20 milliseconds to 12 hours, providing alternative to data acquisition devices and paper chart recorders.

Sampling Interval

Enabled Channel

Logging Capacity

1 minute

1

3.98 years

1 minute

2

727 days

1 minute

8

181 days

10 seconds

1

242 days

10 seconds

2

121 days

10 seconds

8

30 days

1 second

1

24 days

1 second

2

12 days

1 second

8

3 days

100 milliseconds

1

58 hours

100 milliseconds

2

29 hours

100 milliseconds

8

7.2 hours

Site-Log data logger contains one internal thermistor channel, and seven external process signal channels. The 16-bit analog-to-digital converter makes the measurements more precise and accurate. Besides the on-board thermistor channel, the LFC-1 logger has seven external thermocouple input channels used to measure temperature.

The following figure illustrates the correct input connections:

The Site-Log data logger also provides alarm outputs controlled by the low and high programmable alarm thresholds of each enabled channel. The alarm control outputs can be used to turn on/off external alarm devices such as strobe lights, sirens or alarm telephone diallers.

Site-Log data logger also has an excitation control output used to switch the power supply of the external transducer/transmitter, so that these are only powered during a reading, saving on transducer battery consumption.

Site-Log data logger also has a rugged, splash resistant aluminum enclosure and internal electronics are protected against moisture ingress by conformal coating.

All Site-Log series data loggers come with an USB and an AUX ports. The USB port is for connecting directly to the computer. The AUX port is for connecting to a serial communication device like a Modem or an Serial Device Server when the logger needs to be accessed remotely.

 

SiteView Software

 

SiteView is a PC based application which works with Site-Log Series data loggers for downloading, configuration and data analysing and plotting. Its user-friendly graphic interface plus powerful functionalities fit both novice and advanced users.

The versatility of custom equation and custom-line equation handle complicated measurement requirements.

 

SSV-1

  • Support USB, Serial port and Ethernet connections for easy local and remote access

  • Fast communication speed up to 115200 bps makes downloading fast
  • Real-time view and chart recording replaces chart recording device
  • Custom equation and custom-line equation solves scientific and laboratory algorithm difficulties
  • Zoom in/zoom out, annotation/label of graph functions provide detailed view of data
  • Multiple file loading allows easy data comparison.
  • Dynamic statistics provides detailed information of current zoomed view

SiteView Manual >>

Features

Logger Interaction

  • Status View: View status of the connected logger

  • Configuration: Configure logger for new recording session
  • Real-time View: Monitor logger in real-time list view or chart view. Real-time data optionally can be saved to time stamped text files.

Graphing

  • Views: Tabular, graph view, statistics

  • Configuration: Configure axis, lines, view properties
  • Zoom: Zoom in, zoom out, scale zoom, box zoom, time-span zoom
  • Label and Annotation: Add, edit, delete graph labels and line annotations

Measurement conversion

  • Custom Equation: Add, edit, delete custom equation

  • Custom-Line Equation: Add, edit, delete custom-line equation
  • Unit and Subunit: Add, edit, remove unit and subunit

Data Importing/Exporting

  • SiteView File:

    •  Load single or multiple SiteView files into one viewport

    • Export graph to images: Emf, PNG, Gif, Jpeg, Tiff, Bmp file format
    • Export graph to text: csv, txt
    • Save multiple SiteView files to single SiteView file
    • Print graph, tabular data, statiscis.
  • Equations & Units
    • Import, Export Equation files and Unit files.

 

Ethernet and Modem Support

 

There is an AUX port for connecting to a serial communication device like a Modem or an Serial Device Server when the logger needs to be accessed remotely. A SL-Rs232 converter cable is available that terminates in a standard RS232 connector.

SL-RS232

 

SL-RS232 Converter is used to convert Site-Log data logger's TTL level communication signal to RS232 standard.

Applications of SL-RS232 Converter:

  • Computer only has COM port : If the computer does not have any USB port, or if you want to use COM port of the computer to communicate with a Site-Log data logger.

  • Host device is not computer: If the host device is not a computer but it has a RS232 communications port.

 

RS232 to Ethernet Converters

A range of general purpose RS232 to Ethernet or WiFi converters to allow the Site-Log range to be configured and read over a LAN or WiFi Network (requires the SL-RS232)

More Information >>

 

WirelessCOM/G10 GPRS Modem

The WirelessCOM/G10 will allow the Site-Log range to be configured and read remotely over a GPRS mobile phone network (requires the SL-RS232 and a suitable GPRS SIM Card))

More Information >>

 

 

 

Phone +44(0)1765 677425 | Fax +44(0)1765 676650