Operator
Interface Interfaces (HMIs) provide much more versatility than
traditional mechanical control panels. An HMI allows a plant floor
operator to monitor current conditions of a control system and, if
necessary, initiate a change in the operation of the system. HMIs
connect to programmable logic controllers (PLCs) typically through
the serial communications port. The HMI can be programmed to monitor
and/or change current values stored in the data memory of the PLC.
HMIs
can have either text or graphics based displays. A text based HMI
can display printable text characters but can not print graphics.
Some HMIs use touch screen displays while others use a PCB based
keypad. PCB based keypads are best used in applications in which the
keypad is likely to become dirty. A touch screen HMI provides much
more flexibility than typical PCB based keypad displays. Keys can be
created in a touch screen HMI that can be made visible only when needed.
The
HMIs are available in both text display based HMI and graphics
display based HMIs.
 |
|
HMI
Studio is a FREE windows based user friendly software for HMI
configuration and front-end application development. Many ready made
objects are available for fast application development like Data
Entry, Data Display, Text, Bit Lamp, Word Lamp, Real time trends,
Historical trends, Real time alarms, Historical alarms, Date, Time,
Button, Single bar graph, Multiple Bar Graph, Analog Meter, Multi
language Text, Bit map selection, Rectangle, Circle, Lines etc. Other
tools include tag database, PLC driver selection, Network
configuration, ladder programming and data logger.
More
Information >>
|
 |
|
Memory
table for HMI
o Data Registers: 1000
o Retentive Data Registers: 1400
o System Registers: 64
o System coils: 100
o Internal coils: 5000
o Timers: 128
o Non Retentive counters: 128
o Retentive counters: 50
Environmental
o Operating temperature: 0°C to 50°C
o Storage temperature: -20°C to 50°C
o Humidity: 10% to 90% non-condensing
o Emmissions: EN55011 CISPR A
o Immunity to ESD: Level 3 as per IEC1000-4-2
o Immunity to Transiants: Level 3 as per IEC1000-4-4
o Immunity to Radiated RF: Level 3 as per IEC1000-4-3
o Immunity to Conducted RF: Level 3 as per IEC1000-4-6
o Vibration resistance: 10 Hz-150 Hz, a=1.5g
o Shock resistance:
+
Accel:490.5 m/s
+ Pulse width: 11 mS
o Protection-Begel: IP65 Keypad for HMI 201 |
Supported
PLC's, Inverters & Controllers
-
ABB:
AC31
- Allen
Bradley: Micrologix 1000, 1200, 1500, SLC 5/0X
- Aromat:
FP0, FP2, FP3, FP Sigma
- ASCII
Driver: Universal ASCII
- Control
Techniques: All Modbus
- Danfoss:
VLT2800, VLT5000
- Delta:
DVP14ES, 32ES, 32XP, 12SA
- FATEK
PLC: F8s
- Eurotherm:
All Modbus
- GE-SNP:
90-30
- GE-SNPX:
90-30
- Honeywell:
Modbus, ASCII
- Idec:
Micro, Micro Smart
- Keyence:
KV Series, KN10, 16, 24, 40, 80, 300
- Koyo:
DL230, DL240, DL250
- LG
Master: K Series, 10S, 30S, 60S, 100S, 50H, 200H, 200S, 300S, 1000S, 80S
- Mentor
Drives: II, CommanderSE
- Mitsubishi:
FX Series
- Modicon:
Modbus
- Omron:
K, H, CQM, CPM1, CPM2, Cs1, CJ1
- Siemens:
S7-micro, 212, 214, 221, 222, 224, 226, S7-300
- Toshiba:
T Series, T1, T2, T3
- Toshiba
Inverters: S9, G7, S7, S11, A7, G3
- Yokogawa:
F3SP05,
|