Home Page

Contact Us

My Basket

Checkout

HDS1022M Handheld DSO 100MSPS


Description

 

The HDS1022M handheld DSO has been specifically designed for the engineer or technician that requires an oscilloscope to be used on the bench or out in the field. Not only a fast, accurate Digital Storage Oscilloscope but the HDS1022M also incorporates a multi-function Digital Multimeter. The HDS1022M features a ruggered impact resistant casing, easy-to-use controls and high-brightness quality Sony LCD display. Battery life in an exceptional 6 hours. The HDS1022M with a generous array of standard accessories.

 

Product

 

 

 

  • Handheld 2-Channel Digital Storage Oscillscope

  • Sample rate up to 100MSPS, 20MHz bandwidth
  • 12k/channel memory depth
  • 3-3/4 digit DMM with datalogger
  • Manual cursor measurement
  • Li-ion battery and AC adapter
  • 6 hour battery life
  • 9.7 cm 320x240 Sony Colour LCD Display
  • RS-232, USB port for programming & data transferring
  • Edge triggering, video triggering, 5 automatic measurement
  • Independently floating isolated scope and DMM channels for safety
  • A profession ideal tool for design, maintenance and examination
  • Supplied complete with carry case, scope and DMM leads, CD and manual

User Manual >>

 

Description

 

The HDS1022M is a handheld battery powered dual channel Digital Sampling Oscilloscope and Multimeter in one. It features a quality colour LCD display, easy-to-use controls and long battery life.

The HDS1022M comes complete with a wide range of useful functions, usualy only available in higher priced alternatives.

Display Modes

  • Normal - operates like a normal DSO with simple manual control of timebase, triggering etc

  • XY Mode - With the XY mode selected, CH1 is displayed on the horizontal axis and CH2 is on the vertical axis; when the oscilloscope is under the sampling mode in which no trigger is found, the data appears as light spots.
  • Auto-set - The Auto-Set feature lets the Oscilloscope display and measure unknown signals automatically. This function optimizes the position, range, timebase and triggering and assures a stable display of virtually any waveform.
  • Average Display - the displayed waveform is an average of a preset number of waveform samples. This can eleiminate noise which can otherwise obscure readings
  • Persistence mode - in this mode, the screen is not cleared in-between displaying a new waveform sample. Useful for detecting spurious waveform events which would otherwise be missed.
  • Peak Detection - The oscilloscope takes samples from the maximum and minimum of signals in each sampling interval - used to detect a jamming glitch and reduce the possibity of blurring
  • Automatic Measurements - The oscilloscope can perform 5 types automatic measurements such as frequency, cycle, average value, peak-to-peak value and root mean square value. And gives two kinds of measurement results simultaneously on the screen.
  • MATHS functions - shows the result of adding, subtracting, multiplying or dividing calculation on CH1 and CH2 channel waveforms

 

Waveform Display

Persistence mode

Video Signal Capture

Triggering

There are two triggering modes including Edge triggering and Video triggering.

  • Edge triggering: The Edge triggering is a mode by which trigger occurs at the triggering threshold value of the input signal edge. With the Edge triggering selected, the trigger happens on the rise or fall edge of the input signal

  • Video triggering: With Video triggering selected, the oscilloscope performs the NTSC, PAL or SECAM standard video signals field or line trigger

Multimeter

The HDS1022 can also be used in Multimeter mode, and used to make the following measurement;

  • Direct voltage measurement

  • Alternating voltage measurement
  • Direct current measurement
  • Alternating current measurement
  • Resistance measurement

  • Diode measurement
  • Continuity buzzer measurement
  • Capacitance measurement

 

 
Other Features

  • Waveform Storage - up to 4 waveforms can be saved in the HDS1022M's internal memory for comparison display or upload to a PC

  • Data Upload to a PC - Stored Data can be uploaded to a PC via Rs232 or USB in bitmap or ASCII format.

 

 

Specifications

 
DSO

Sampling

Sampling modes

Normal sampling
Peak detection
Average value

Sampling rate

100 MS/s

Input

Input coupling

DC, AC

Input impedance

1MOhm;±2% connected in parallel with 20pF±3pF

Probe attenuation coefficient

1X, 10X, 100X, 1000X

Max. Input voltage

400V (peak)

Channel delay time (typical)

150ps

Horizontal

Sampling rate range

10S/s 100MS/s

Waveform interpolation

sin x / x

Record length

6K points on each channel

Scanning speed range S/div

5ns/div 5s/div, stepping in the “1-2.5-5” mode.

Sampling rate and relay time accuracy

±100ppm(any time interval which is equal to or larger than 1ms)

Time interval
(T)measurement accuracy full bandwidth

Single: ±(1 sampling interval time+100ppm×reading+0.6ns)
>average 16 : ±(1 sampling interval time +100ppm×reading+0.4ns)

Vertical

Analog digital converter A/D

With the resolution of 8 bits, make sampling on both channels synchronously.

Sensitivity range V/div

5mV/div 5V/div at the input BNC

Displacement range

±50V(500mV 5V), ±1V(5mV 200mV)

Analog bandwidth

20MHz

Low frequency response AD coupling, -3dB

5Hz at the BNC

Rise time typical one at the BNC

17.5ns

DC gain accuracy

5%

DC measurement accuracy average value sampling mode

The voltage difference (V) between any two points on the waveform after averaging the captured waveforms more than16: ±(5% reading + 0.05 divisions).

Trigger

Trigger sensitivity Edge triggering

DC coupling : CH1 and CH2: 1div(DC full bandwidth)
AC coupling : Same as the DC coupling when it is equal to or larger than 50Hz.

Triggering lever range

±6 divisions from the screen center

Triggering level accuracy (typical) which is applicable to the signal with rise and fall time equal to or longer than 20ns

±0.3 divisions

Trigger displacement

655 divisions for pre-triggering and 4 divisions for post- triggering

Make a 50% level setting (Typical)

Operation with the input signal frequency equal to or larger than 50Hz.

Trigger sensitivity (Video triggering and typical mode)

2 divisions of peak-to-peak value

Signal system and line/field frequency (Video triggering mode)

Support the NTSC, PAL and SECAM broadcasting systems of any field or line frequency.

Measurement

Cursor measurement

Voltage difference (V) and time difference (T) between cursors

Auto measurement

Peak-to-peak value, average value, root mean square value, frequency and cycle.

Multimeter

Voltage (VAC) TRMS

Input Impedance

10MΩ

Max. Input Voltage

1000V (DC or AC peak-to-peak value)

Range

Accuracy

Resolution

400.0mv

±1%±1 digit

100uV

4.000V

1mV

4.000V

10mV

4.000V

100mV

Voltage (VAC)

Input Impedance

10MΩ

Max. Input Voltage

750V (AC, virtual value)

Frequency range

from 40Hz to 400Hz.

Display

Virtual value of the sine wave

Range

Accuracy

Resolution

4.000V

±1%±3 digit

1mV

4.000V

10mV

4.000V

100mV

Voltage (VAC)

Range

Accuracy

Resolution

40.00mA

±1%±1 digit

10uA

400.0mA

±1.5%±1 digit

100uA

20A

±3%±3 digit

10mA

Resistance

Range

Accuracy

Resolution

400.0Ω

±1%±3 digit

0.1Ω

4.000KΩ

±1%±1 digit

1Ω

40.00KΩ

10Ω

400.0KΩ

100Ω

4.000MΩ

1KΩ

40.00MΩ

±1.5%±1 digit

10KΩ

Capacitance

Range

Accuracy

Resolution

51.20nF

±3%±3 digit

10pF

512.0nF

100pF

5.120uF

1nF

51.20uF

10nF

100uF

100nF

Diode

Voltage reading

0V - 1.5V

On-off Test

0V - 1.5V

 
General

Display

Display type

3.8’’ color liquid crystal display

Display resolution

320 (horizontal) × 240 (vertical) pixels

Display color

4096 colors

Operating Temperature

Used battery

0 to 50 °C (32 to 122 °F)

Power adapter

0 to 40 °C (32 to 104 °F)

Storage Temperature

Storage

-20 to +60 °C(-4 to +140 °F)

Operating Humidity

0 to 10 °C
(32 to 50 °F)

no condensation

10 to 30 °C
(50 to 86 °F)

95 %

30 to 40 °C
(86 to 104 °F)

75 %

40 to 50 °C
(104 to 122 °F)

45 %

Storage Humidity

-20 to +60 °C
(-4 to +140 °F)

no condensation

Accessories

Two 1:1 (10:1) passive oscilloscope probes of 1.2 meters long
A pair of test leads of multimeter
A piece of serial-port data transmission line
A measuring extension module for small current
A measuring extension module for small capacitance
A power adapter in conformity with the standards of the host country
A User Manual
An operational optical disk

 

 

Phone +44(0)115 925 8412 | Fax +44(0)115 925 9757