EL-USB-V USB Voltage Datalogger


Description

 

The EL-USB-V is a voltage data logger that will collect up to 32,510 voltage readings over a 0 to 30V DC range. The collected data is simply downloaded to a PC via a USB port, where it can be analysed, printed or exported to other programs using the included, purpose designed software. The unit may also be set up via the software so that logger name, measurement rate, high and low alarms and start date and time may be adjusted to the required value. Supplied with a set of crocodile clip terminated test leads and featuring a pair of screw terminals, this data logger can accept measurements from a wide range of sensors and is suitable for use in a wide range of applications.

 

Features

 

 

 

  • Voltage measurement range 0 to 30V DC

  • Memory: 32,510 voltage readings
  • Unit set-up and data download via simple USB connection
  • Includes Windows software for unit configuration and data manipulation
  • Programmable sample rates
  • LED indication for unit status
  • Two user-programmable alarm thresholds
  • Data stored in non-volatile memory
  • Connection via two screw terminals housed in cap Data stored in non-volatile memory
  • Powered by 1x ½AA 3.6V lithium battery (supplied)
  • Battery Life: 1 year (at 25°C and 1 minute logging interval)
  • Translucent cap for protection to IP67
  • 20mm x 27mm x 103mm

 User Manual >>

 

Description

 

This data logger measures and stores up to 32,510 voltage readings over a 0-30V d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista(32-bit only). The data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a long-life lithium battery. Correct functioning of the unit is indicated by flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a set of measurement leads terminating in crocodile clips

Configuration and data download is simply achieved by removing the IP67 end cap and plugging the logger into a spare USB port.

Data logger configuration software is supplied, allowing the user to easily set-up the data logger. Selectable parameters include logging rate, measurement units, high & low alarms and start-time.

The logged data stored in EL-USB-V is downloaded via the configuration software. Use EasyLog software to stop recording, access the instrument's stored data, and save it to a file that you name on the PC, all in one easy operation. The file format is Excel-compatible. Once downloaded data can be graphed and printed. A cursor allows you to determine signal magnitude and time and date of acquisition for any value, and a magnifier utility allows you to zoom in for a closer look over any range — Easy and fast.

 

 

For more custom analysis and report generation, simply import the stored data file to Microsoft Excel for virtually unlimited flexibility in how you view and interpret your results

 

 

Phone +44(0)115 925 8412 | Fax +44(0)115 925 9757