DSO-3064A
USB Oscilloscope 60MHz
|
|
Description |
|
|
|
The
DSO-3064A is a USB Oscilloscope with four channels featuring a
200MS/s sampling rate, a 60MHz Bandwidth with a 8-bit resolution.
Designed for general signal testing and automotive applications, it
is ideal for the student, hobbyist or engineer, the DSO-3060A has a
small size, low power consumption and high reliability. Supplied with
feature-rich Oscilloscope software package, programming examples and
LabVIEW drivers.
|
|
Product |
|
|
|
|
|

DSO3064A
Includes
4 x scope probes, Carry Case, CD, PSU, USB lead
User
Manual >>
Software
Download >>
|
|
|
|
Software |
|
|
|
 |
|
1.
The Main Menu
All
settings can be found in the main menu.
2.The
Toolbar
3.
Shows the trigger information
It
shows the edge trigger slope, source and level.
4.
The Horizontal Panel
The
user can change Time/Div, format in the panel.
5.
The Vertical Panel
The
user can turn on/off the CH1/CH2. Also the user can change the
CH1/CH2 volt/div, coupling and probe attenuation.
6.
The Trigger Panel
In
this panel, the user can change the trigger mode, sweep, source and slope.
7.
Shows the system time.
8.
Shows the main time base setting.
9.
Marker shows Edge trigger level.
10.
Shows the CH2 information
Readouts
show the coupling of the channels.
Readouts
show the vertical scale factors of the channels.
A
B icon indicates that the channel is bandwidth limited.
11.
Shows the CH1 information
Readouts
show the coupling of the channels.
Readouts
show the vertical scale factors of the channels.
A
B icon indicates that the channel is bandwidth limited. |
12.
Shows the software status.
13.
The markers show the reference points of the displayed waveforms. If
there is no marker, the channel is not displayed.
14.
The same as 13.
15.
A window that shows the display waveform in buffer position.
16.
Marker shows horizontal trigger position.
17.
Trigger status indicates the following:
AUTO:
The oscilloscope is in auto mode and is acquiring waveforms in the
absence of triggers.
TrigD:
The oscilloscope has seen a trigger and is acquiring the post
trigger data.
WAIT:
All pretrigger data has been acquired and the oscilloscope is ready
to accept a trigger.
STOP:
The oscilloscope has stopped acquiring waveform data.
RUN:
The oscilloscope is running.
PLAY:
The oscilloscope is displaying the record waveforms.
|
|
|
|
Software
Features
Autoset:
The function obtains a stable waveform display for you. It
automatically adjusts the vertical scale, horizontal scale and
trigger settings. Auto setup also displays several automatic
measurements in the graticule area, depending on the signal type
Measurements:
Provides 20 parametric auto measurements Vp-p, Vmax, Vmin, Vmean,
Vrms, Vamp, Vhigh, Vlow, positive overshoot, negative overshoot,
cycle mean, cycle rms, period, frequency, positive pulse width,
negative pulse width, rise time (10%~90%), fall time (10%~90%),
positive duty cycle, negative duty cycle
Maths:
The mathematic functions include addition, subtract, multiply and
division for CH1 and CH2
FFT:
You can use the FFT mode to convert a time-domain signal into its
frequency components (spectrum) supports Rectangular, Hanning,
Hamming, Blackman Window.
Cursor:
Time/frequency difference, voltage difference Frequency only in FFT mode
Pass/Fail:
The Pass/Fail function monitors changes of signals and outputs pass
or fail signals by comparing the input signal with the pre-created mask.
Files:
You can save captures waveforms as an image file or as a CSV file
for importation into spreadsheet programs such as Excel. CSV files
can also be recalled and displayed alongside captured data.
|

captured
and saved waveforms

x-y
mode |
|
Print
Test report: Captured waveforms can be printed as a test report
 |

pass/fail
view

|
|
|
What's
Included |
|
|
|
|

4
sets of 1:1/10:1 professional scope probes |

Carry
Case |

All
software on CD |

Printed
manual
|
|
|
|
Specifications
and Requirements |
|
|
|
|
Max.
sample rate |
200MS/s
(Single Channel)
100MS/s
(Dual Channels) |
|
Channels |
4
Channels |
|
Vertical
resolution |
8
bits/channel |
|
Gain
range |
10mV
~ 5V/div @ x1 probe(10mV, 20mV, 50mV, 100mV,
200mV,
500mV, 1V, 2V, 5V/div1,2,5 sequence)
100mV
~ 50V/div @ x10 probe
1V
~ 500V/div @ x100 probe
10V
~ 5KV/div @ x1000 probe |
|
Range |
8
divisions |
|
Offset
level |
+/-4
divisions |
|
Coupling |
AC,
DC,GND |
|
Offset
increments |
0.02
div |
|
Impedance |
1M
ohm |
|
DC
accuracy |
+/-3%
|
|
Input
protection |
35Vpk
(DC + peak AC < 10 kHz, without external attenuation) |
|
Display
Mode |
Y-T,
X-Y |
|
Timebase
range |
5ns/div
~ 1000s/div(1-2-5 sequence) |
|
Acquisition
mode |
Realtime
sampling: 5ns /div ~ 200ms/div.
Roll
mode: 500ms/div ~ 1000s/div |
|
Range |
10
divisions |
|
Buffer
Size |
10K
~ 16M points (Single Channel) |
|
Trigger
Type |
Edge
trigger, Pulse trigger |
|
Trigger
Mode |
Auto,
Normal and Single |
|
Trigger
Autoset |
Yes |
|
Trigger
Range |
10
divisions |
|
Trigger
level |
+/-4
divisions |
|
Measurements |
Vpp,
Vmax, Vmin, Vmean, Vrms, Vamp, Vtop, Vbase,
Vmid,positive
overshoot, negative overshoot, cycle mean,
cycle
RMS, period, frequency, positive pulse width,
negative
pulse width, rise time (10%~90%), fall time
(10%~90%),
positive duty cycle, negative duty cycle |
|
Maths |
Addition,
Subtraction, Multiplication, FFT |
|
FFT |
Rectangular,
Hanning, Hamming, Blackman Window |
|
Interface |
USB2.0
(USB1.1 compatible) |
|
Power |
External
power source required.(8.5-36v dc) |
|
Dimensions |
224
x168 x 37(mm) |
|
|
|
|
Phone