DS5000
Range Bench DSO 500MSPS
|
|
Description |
|
|
|
The
DS5000 range are full-featured two-channel bench-top oscilloscopes
with 8-bit resolution and a 500MSPS sampling rate, available in
either 60MHz, 100MHz and 150MHz bandwidth versions. With a large
colour LCD and advanved features such as automatic measurements, FFT
and Pass/Fail testing, the range makes a valuable addition to any
workshop. Complete with USB interface for downloading captured
waveforms and the free Ultrascope software.
|
|
Product |
|
|
|
|
|
|
|
Description |
|
|
|
|
The
DS5000 range are full-featured 60MHz, 100MHz or 150MHz two-channel
bench-top oscilloscope with 8-bit resolution, perfect for any
Engineers or Technicians desk. With a large colour LCD, the
DS5000 is small enough and light enough to carry anywhere. With a
buffer size of 4K samples, DS5000 sampling range is 500MSPS with
synchronous 8-bit sampling on both channels. Sensitivity range is
5mV/div~5V/div. The USB connection makes printing stored results easy.
|
|
Built-in
Digital Filters
|
|
|
 |
 |
|
The
DS5000 series oscilloscopes have 4 built-in digital filters(low
pass, high pass, band pass and band reject). A convenient function to
analyze and measure real world noisy signals.
|
|
20
Auto-Measurements

DS5000
series features 20 auto-measurements: 10 voltage measurements: Vp-p,
Vamp, Vtop, Vbase, Vmax, Vmin, Vavg, Vrms, overshoot and preshoot; 10
time measureements: frequency, +pulse width, -pulse width, period,
rise time, fall time, +duty, -duty, delay 1-2(rise) and delay 1-2(fall).
|
Maths
Functions

DS5000
provides +, -, x, ÷ and FFT math functions. They can be used to
perform different analysis and measurements. |
|
Waveform
Recorder

Recording
time can be adjusted from 1ms to 1000s. Record lenght varies from 1
to 1000 frames. |
Pass/Fail
Function

The
pass/fail function is based on a user defined rule. It can be used
to find any abnormal signals, or to trig the waveform recorder and
capture desired events.
|
|
UltraScope
Software

The
user can implement the communication between PC and DS5000 through
RS-232, GPIB and USB Device using Ultrascope. User can read
measurement data, waveform and capture data. It can also setup
control panel, store and print waveform, measurement data and capture data.
|
Expansion
Modules
|
 |
EM5-CM
GPIB,
RS-232 communication "Pass/Fail" test |
|
 |
EM5-COM
GPIB,RS-232
communication |
|
 |
EM5-P/F
"Pass/Fail"
test |
|
|
|
|
|
Prices
and Ordering |
|
|
|
|
|
|
|
|
Specifications |
|
|
Model |
DS5152C |
DS5102C |
DS5062C |
|
Bandwidth |
150
MHz |
100
MHz |
60
MHz |
|
Real-Time
Sample Rate |
500
MSa/s |
|
Equivalent
Sample Rate |
50
GSa/s |
|
Rise
Time |
2.3
ns |
3.5
ns |
5.8
ns |
|
Input
Impedance |
1
MΩ || 13 pFï¼50 Ω |
1MΩ
|| 13 pF |
|
Time
Base Range |
1
ns/div to 50 s/div |
2
ns/div to 50 s/div |
5
ns/div to 50 s/div |
|
X-Y
Operation |
Bandwidth |
150
MHz |
100
MHz |
60
MHz |
|
|
|
|
|
Common
Parameters |
|
Channels |
Dual
Channels + External Trigger |
|
Memory
Depth |
4K
points per channel |
|
Vertical
Sensitivity |
2
mV/div to 5 V/div |
|
Vertical
Resolution |
8
bits |
|
Input
Coupling A1 & A2 |
DC,
AC, Ground |
|
Trigger
Modes |
Edge,
Video, Pulse Width, Delay |
|
Trigger
Sweep Modes |
Auto,
Normal, Single |
|
Trigger |
CH1,
CH2, Ext, Ext/5, AC line |
|
Horizontal
Time Accuracy |
±
0.01% |
|
Maximum
Input Voltage |
400
V(DC + AC peak, 1 MΩ Input Impedance, 10X), 5 V (Vrms,
50 Ω Input Impedance, BNC) |
|
Math |
Add,
Subtract, Multiply, Divide, Reverse |
|
Automatic
Measurements |
Vpp,
Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Preshoot, Overshoot,
Frequency, Period, Rise Time, Fall Time, Positive Width, Negative
Width, Positive Duty Cycle, Negative Duty Cycle, Delay 1â2 ,
Delay 1â2 |
|
Cursor
Measurements |
Manual,
Track and Auto Measure modes |
|
Storage |
10
Waveforms and Setups |
|
FFT |
Window
modes |
Hanning,
Hamming, Blackman-Harrisï, Rectangular |
|
Sample
Size |
1024
points |
|
Power |
Worldwide
Use, 100 - 240 V / 40 VA Max |
|
Weight |
4.5
kg |
|
|
|
|
|
Phone
+44(0)115 925 8412 | Fax +44(0)115 925 9757 |