User
Manual >> |
|
|
Model
5C7-252 Series Controllers are temperature controls with an RS-232
communications port allowing them to be confiqured for different
modes of operation from a personal computer. The controllers are
provided with PC Software and a Graphical user interface. (GUI) Once
the controller is configured, the PC may be disconnected and the
controller can be operated as a stand-alone unit. Communications can
be re-established at any time to adjust the settings. All parameter
settings are retained in non-volatile memory.
The
controller package consists of a printed circuit card mounted to a
metal mounting bracket that is DIN compatible and may be mounted
either horizontally or vertically. The controller can be operated
from either 120 VAC or 240 VAC which is field selectable. Input and
power outputs are made via .250 and .110 fast tab connections. The
sensor inputs and RS232 connections are via a Eurostyle screw
terminal strip. A solid state relay output provides current
capability up to 15 amperes at either 120 VAC or 240 VAC. In
addition, an alarm output solid state relay is provided which is
rated for 0.5 ampere at either 120 VAC or 240 VAC plus a 5 volt drive
signal rated at 20 ma for an optional LED alarm monitor, solid state
relay, or reed relay.
|
|
The
PC permits the monitoring of actual temperature, set temperature,
percent of power applied to the load, and alarm status. It allows
selection of the set temperature, turning the power on or off,
canceling an alarm condition by silencing the PC audio alarm, tuning
the controller setting parameters and displaying the current sensor selection.
Controller
tuning parameters consists of proportional bandwidth (P), integral
gain in repeats per minute (I), and the derivative rate in minutes
(D) for selecting P, PI, PD, or PID operation. An on/off operating
mode with an adjustable hysteresis may also be selected. A controller
configuration command allows for additional optional settings.
The
configuration mode allows the operator to select the applicable type
thermistor input, type of optional auxiliary input, set control
limits for the application, give the controller an identifying name,
select either heating or cooling mode, plus select and enable a
protective password.
The
three thermistor selections have an operating temperature range of
-20°C to 110°C for TS67, 50°C to 225°C for TS133,
and 70°C to 300°C for TX2A.
|

|